Bundles of thick-walled microducts MTB WPP-MG

Bundles of thick-walled microducts MTB WPP-MG in thin, tight sheath; with flat cross-section; designed for direct burying underground. The flat design allows vertical installation, which reduces the cost of installation in the lane.

The configuration of the number and diameters of the microducts can be adjusted to a customer’s individual needs.

The thin sheath, that can be removed, ensures easy separation and extraction of the individual microducts.  

Bundles can be produced with locating wire (prefabricated inside) in order to localize the route of bundles in future. 

Standard color of the outer sheath – orange.

Do you have any questions?

Ask for the product
Lp.

Marking

Width B1

Height B2

Minimal thickness of the sheath

[mm]

[mm]

[mm]

1

MTB WPP-MG-4×8/4mm

33,6

9,6

0,8

2

MTB WPP-MG-5×8/4mm

41,6

9,6

0,8

3

MTB WPP-MG-7×8/4mm

57,6

9,6

0,8

4

MTB WPP-MG-4×10/6mm

41,6

11,6

0,8

5

MTB WPP-MG-5×10/6mm

51,6

11,6

0,8

6

MTB WPP-MG-7×10/6mm

71,6

11,6

0,8

7

MTB WPP-MG-4×12/8mm

49,6

13,6

0,8

8

MTB WPP-MG-5×12/8mm

61,6

9,6

0,8

9

MTB WPP-MG-7×12/8mm

85,6

13,6

0,8

MTB WPP-MG

4×8/4

5×8/4

7×8/4

4×10/6

5×10/6

7×10/6

4×12/8

5×12/8

7×12/8

Dimensions of the bundle [mm]

Width B1

33,6

41,6

57,6

41,6

51,6

71,6

49,6

61,6

85,6

Height B2

9,6

9,6

9,6

11,6

11,6

11,6

13,6

13,6

13,6

Number of microducts in bundle

4

5

7

4

5

7

4

5

7

Dimensions of microducts

(outer diameter / inner diameter)   [mm]

8 / 4

10 / 6

12 / 8

Maximum installation tensile force [N]

1600

2150

3010

2750

3400

4700

3360

4200

5900

Minimum bending radius [mm]

96

96

96

116

116

116

136

136

136

Minimal thickness of the sheath [mm]

> 0,8

Transport, storage and exploitation temperature range [°C]

-40°C to + 70°C

Installation temperature range [°C]

-10°C to + 50°C

Typical winding length [m]

2000

2000

2000

2000

2000

2000

2000

2000

2000

Weight [kg/km]

166

202

273

219

267

361

272

331

450